Journal Articles
2020
Carroll, Liam; Croteau, Etienne; Kertzscher, Gustavo; Sarrhini, Otman; Turgeon, Vincent; Lecomte, Roger; Enger, Shirin A.
In: Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB), vol. 76, pp. 92–99, 2020, ISSN: 1724-191X.
Abstract | Links | BibTeX | Tags: Algorithms, Arterial input function, Arteries, Dynamic PET, Electrons, Humans, Imaging, Non-invasive detector development, Phantoms, Positron-Emission Tomography, Scintillation
@article{carroll_cross-validation_2020,
title = {Cross-validation of a non-invasive positron detector to measure the arterial input function for pharmacokinetic modelling in dynamic positron emission tomography},
author = {Liam Carroll and Etienne Croteau and Gustavo Kertzscher and Otman Sarrhini and Vincent Turgeon and Roger Lecomte and Shirin A. Enger},
doi = {10.1016/j.ejmp.2020.06.009},
issn = {1724-191X},
year = {2020},
date = {2020-08-01},
journal = {Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB)},
volume = {76},
pages = {92--99},
abstract = {Kinetic modeling of positron emission tomography (PET) data can assess index rate of uptake, metabolism and predict disease progression more accurately than conventional static PET. However, it requires knowledge of the time-course of the arterial blood radioactivity concentration, called the arterial input function (AIF). The gold standard to acquire the AIF is by invasive means. The purpose of this study was to validate a previously developed dual readout scintillating fiber-based non-invasive positron detector, hereinafter called non-invasive detector (NID), developed to determine the AIF for dynamic PET measured from the human radial artery. The NID consisted of a 3 m long plastic scintillating fiber with each end coupled to a 5 m long transmission fiber followed by a silicon photomultiplier. The scintillating fiber was enclosed inside the grooves of a plastic cylindrical shell. Two sets of experiments were performed to test the NID against a previously validated microfluidic positron detector. A closed-loop microfluidic system combined with a wrist phantom was used. During the first experiment, the three PET radioisotopes 18F, 11C and 68Ga were tested. After optimizing the detector, a second series of tests were performed using only 18F and 11C. The maximum pulse amplitude to electronic noise ratio was 52 obtained with 11C. Linear regressions showed a linear relation between the two detectors. These preliminary results show that the NID can accurately detect positrons from a patient's wrist and has the potential to non-invasively measure the AIF during a dynamic PET scan. The accuracy of these measurements needs to be determined.},
keywords = {Algorithms, Arterial input function, Arteries, Dynamic PET, Electrons, Humans, Imaging, Non-invasive detector development, Phantoms, Positron-Emission Tomography, Scintillation},
pubstate = {published},
tppubtype = {article}
}
Kinetic modeling of positron emission tomography (PET) data can assess index rate of uptake, metabolism and predict disease progression more accurately than conventional static PET. However, it requires knowledge of the time-course of the arterial blood radioactivity concentration, called the arterial input function (AIF). The gold standard to acquire the AIF is by invasive means. The purpose of this study was to validate a previously developed dual readout scintillating fiber-based non-invasive positron detector, hereinafter called non-invasive detector (NID), developed to determine the AIF for dynamic PET measured from the human radial artery. The NID consisted of a 3 m long plastic scintillating fiber with each end coupled to a 5 m long transmission fiber followed by a silicon photomultiplier. The scintillating fiber was enclosed inside the grooves of a plastic cylindrical shell. Two sets of experiments were performed to test the NID against a previously validated microfluidic positron detector. A closed-loop microfluidic system combined with a wrist phantom was used. During the first experiment, the three PET radioisotopes 18F, 11C and 68Ga were tested. After optimizing the detector, a second series of tests were performed using only 18F and 11C. The maximum pulse amplitude to electronic noise ratio was 52 obtained with 11C. Linear regressions showed a linear relation between the two detectors. These preliminary results show that the NID can accurately detect positrons from a patient’s wrist and has the potential to non-invasively measure the AIF during a dynamic PET scan. The accuracy of these measurements needs to be determined.2019
Turgeon, Vincent; Kertzscher, Gustavo; Carroll, Liam; Hopewell, Robert; Massarweh, Gassan; Enger, Shirin A.
Characterization of scintillating fibers for use as positron detector in positron emission tomography Journal Article
In: Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB), vol. 65, pp. 114–120, 2019, ISSN: 1724-191X.
Abstract | Links | BibTeX | Tags: Arterial input function, Dynamic PET, Electrons, Positron-Emission Tomography, Radiation detector, Scintillating fibers, Scintillation Counting
@article{turgeon_characterization_2019,
title = {Characterization of scintillating fibers for use as positron detector in positron emission tomography},
author = {Vincent Turgeon and Gustavo Kertzscher and Liam Carroll and Robert Hopewell and Gassan Massarweh and Shirin A. Enger},
doi = {10.1016/j.ejmp.2019.08.009},
issn = {1724-191X},
year = {2019},
date = {2019-09-01},
journal = {Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB)},
volume = {65},
pages = {114--120},
abstract = {PURPOSE: Manual and automatic blood sampling at different time intervals is considered the gold standard to determine the arterial input function (AIF) in dynamic positron emission tomography (PET). However, blood sampling is characterized by poor time resolution and is an invasive procedure. The aim of this study was to characterize the scintillating fibers used to develop a non-invasive positron detector.
METHODS: The detector consists of a scintillating fiber coupled at each end to transmission fiber-optic cables that are connected to photo multiplier tubes in a dual readout setup. The detector is designed to be wrapped around the wrist of the patient undergoing dynamic PET. The attenuation length and bending losses were measured with excitation from gamma radiation (137Cs) and ultraviolet (UV) light. The response to positron-emitting radio-tracers was evaluated with 18F and 11C.
RESULTS: The attenuation length for a 3.0 m and 1.5 m long scintillating fiber both coincides with the attenuation length given by the manufacturer when excited with the 137Cs source, but not with the UV source due to the differences in scintillation mechanisms. The bending losses are smaller than the measurement uncertainty for the 137Cs source irradiation, and increase when the bending radius decrease for the UV source irradiation. The signal-to-noise ratio for 18F and 11C solutions are 1.98 and 22.54 respectively. The measured decay constant of 11C agrees with its characteristic value.
CONCLUSION: The performed measurements in the dual readout configuration suggest that scintillating fibers may be suitable to determine the AIF non-invasively.},
keywords = {Arterial input function, Dynamic PET, Electrons, Positron-Emission Tomography, Radiation detector, Scintillating fibers, Scintillation Counting},
pubstate = {published},
tppubtype = {article}
}
PURPOSE: Manual and automatic blood sampling at different time intervals is considered the gold standard to determine the arterial input function (AIF) in dynamic positron emission tomography (PET). However, blood sampling is characterized by poor time resolution and is an invasive procedure. The aim of this study was to characterize the scintillating fibers used to develop a non-invasive positron detector.
METHODS: The detector consists of a scintillating fiber coupled at each end to transmission fiber-optic cables that are connected to photo multiplier tubes in a dual readout setup. The detector is designed to be wrapped around the wrist of the patient undergoing dynamic PET. The attenuation length and bending losses were measured with excitation from gamma radiation (137Cs) and ultraviolet (UV) light. The response to positron-emitting radio-tracers was evaluated with 18F and 11C.
RESULTS: The attenuation length for a 3.0 m and 1.5 m long scintillating fiber both coincides with the attenuation length given by the manufacturer when excited with the 137Cs source, but not with the UV source due to the differences in scintillation mechanisms. The bending losses are smaller than the measurement uncertainty for the 137Cs source irradiation, and increase when the bending radius decrease for the UV source irradiation. The signal-to-noise ratio for 18F and 11C solutions are 1.98 and 22.54 respectively. The measured decay constant of 11C agrees with its characteristic value.
CONCLUSION: The performed measurements in the dual readout configuration suggest that scintillating fibers may be suitable to determine the AIF non-invasively.2017
Famulari, Gabriel; Pater, Piotr; Enger, Shirin A.
Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm Journal Article
In: Physics in Medicine and Biology, vol. 62, no. 13, pp. 5495–5508, 2017, ISSN: 1361-6560.
Abstract | Links | BibTeX | Tags: Algorithms, DNA, DNA Damage, Electrons, Imaging, Monte Carlo Method, Phantoms, Photons, Radiometry
@article{famulari_microdosimetry_2017,
title = {Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm},
author = {Gabriel Famulari and Piotr Pater and Shirin A. Enger},
doi = {10.1088/1361-6560/aa71f6},
issn = {1361-6560},
year = {2017},
date = {2017-07-01},
journal = {Physics in Medicine and Biology},
volume = {62},
number = {13},
pages = {5495--5508},
abstract = {The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(textgreaterE)/f(textgreater0) and dose mean lineal energy ([Formula: see text]) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The [Formula: see text] values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length ([Formula: see text]), the [Formula: see text] calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of [Formula: see text] values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.},
keywords = {Algorithms, DNA, DNA Damage, Electrons, Imaging, Monte Carlo Method, Phantoms, Photons, Radiometry},
pubstate = {published},
tppubtype = {article}
}
The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(textgreaterE)/f(textgreater0) and dose mean lineal energy ([Formula: see text]) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The [Formula: see text] values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length ([Formula: see text]), the [Formula: see text] calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of [Formula: see text] values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.2011
Enger, Shirin A.; D’Amours, Michel; Beaulieu, Luc
Modeling a hypothetical 170Tm source for brachytherapy applications Journal Article
In: Medical Physics, vol. 38, no. 10, pp. 5307–5310, 2011, ISSN: 0094-2405.
Abstract | Links | BibTeX | Tags: Algorithms, Brachytherapy, Computer Simulation, Computer-Assisted, Electrons, Equipment Design, Gold, Humans, Models, Monte Carlo Method, Photons, Platinum, Radioisotopes, Radiotherapy Planning, Stainless Steel, Theoretical, Thulium, Titanium
@article{enger_modeling_2011,
title = {Modeling a hypothetical 170Tm source for brachytherapy applications},
author = {Shirin A. Enger and Michel D'Amours and Luc Beaulieu},
doi = {10.1118/1.3626482},
issn = {0094-2405},
year = {2011},
date = {2011-10-01},
journal = {Medical Physics},
volume = {38},
number = {10},
pages = {5307--5310},
abstract = {PURPOSE: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical (170)Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons.
METHODS: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of (170)Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical (170)Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation.
RESULTS: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount (textless1%) in water. Platinum encapsulation resulted in bremsstrahlung effects similar to those with the gold encapsulation. The range of the beta particles decreases by 1.1 mm with the stainless-steel encapsulation compared to the bare source but the tissue will still receive dose from the beta particles several millimeters from the source capsule. The gold and platinum capsules not only absorb most of the electrons but also attenuate low energy photons. The mean energy of the photons escaping the core and the stainless-steel capsule is 113 keV while for the gold and platinum the mean energy is 160 keV and 165 keV, respectively.
CONCLUSIONS: A (170)Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our results, the use of (170)Tm as a brachytherapy source presents notable challenges.},
keywords = {Algorithms, Brachytherapy, Computer Simulation, Computer-Assisted, Electrons, Equipment Design, Gold, Humans, Models, Monte Carlo Method, Photons, Platinum, Radioisotopes, Radiotherapy Planning, Stainless Steel, Theoretical, Thulium, Titanium},
pubstate = {published},
tppubtype = {article}
}
PURPOSE: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical (170)Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons.
METHODS: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of (170)Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical (170)Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation.
RESULTS: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount (textless1%) in water. Platinum encapsulation resulted in bremsstrahlung effects similar to those with the gold encapsulation. The range of the beta particles decreases by 1.1 mm with the stainless-steel encapsulation compared to the bare source but the tissue will still receive dose from the beta particles several millimeters from the source capsule. The gold and platinum capsules not only absorb most of the electrons but also attenuate low energy photons. The mean energy of the photons escaping the core and the stainless-steel capsule is 113 keV while for the gold and platinum the mean energy is 160 keV and 165 keV, respectively.
CONCLUSIONS: A (170)Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our results, the use of (170)Tm as a brachytherapy source presents notable challenges.
Journal Articles
2020
Carroll, Liam; Croteau, Etienne; Kertzscher, Gustavo; Sarrhini, Otman; Turgeon, Vincent; Lecomte, Roger; Enger, Shirin A.
In: Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB), vol. 76, pp. 92–99, 2020, ISSN: 1724-191X.
Abstract | Links | BibTeX | Tags: Algorithms, Arterial input function, Arteries, Dynamic PET, Electrons, Humans, Imaging, Non-invasive detector development, Phantoms, Positron-Emission Tomography, Scintillation
@article{carroll_cross-validation_2020,
title = {Cross-validation of a non-invasive positron detector to measure the arterial input function for pharmacokinetic modelling in dynamic positron emission tomography},
author = {Liam Carroll and Etienne Croteau and Gustavo Kertzscher and Otman Sarrhini and Vincent Turgeon and Roger Lecomte and Shirin A. Enger},
doi = {10.1016/j.ejmp.2020.06.009},
issn = {1724-191X},
year = {2020},
date = {2020-08-01},
journal = {Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB)},
volume = {76},
pages = {92--99},
abstract = {Kinetic modeling of positron emission tomography (PET) data can assess index rate of uptake, metabolism and predict disease progression more accurately than conventional static PET. However, it requires knowledge of the time-course of the arterial blood radioactivity concentration, called the arterial input function (AIF). The gold standard to acquire the AIF is by invasive means. The purpose of this study was to validate a previously developed dual readout scintillating fiber-based non-invasive positron detector, hereinafter called non-invasive detector (NID), developed to determine the AIF for dynamic PET measured from the human radial artery. The NID consisted of a 3 m long plastic scintillating fiber with each end coupled to a 5 m long transmission fiber followed by a silicon photomultiplier. The scintillating fiber was enclosed inside the grooves of a plastic cylindrical shell. Two sets of experiments were performed to test the NID against a previously validated microfluidic positron detector. A closed-loop microfluidic system combined with a wrist phantom was used. During the first experiment, the three PET radioisotopes 18F, 11C and 68Ga were tested. After optimizing the detector, a second series of tests were performed using only 18F and 11C. The maximum pulse amplitude to electronic noise ratio was 52 obtained with 11C. Linear regressions showed a linear relation between the two detectors. These preliminary results show that the NID can accurately detect positrons from a patient's wrist and has the potential to non-invasively measure the AIF during a dynamic PET scan. The accuracy of these measurements needs to be determined.},
keywords = {Algorithms, Arterial input function, Arteries, Dynamic PET, Electrons, Humans, Imaging, Non-invasive detector development, Phantoms, Positron-Emission Tomography, Scintillation},
pubstate = {published},
tppubtype = {article}
}
2019
Turgeon, Vincent; Kertzscher, Gustavo; Carroll, Liam; Hopewell, Robert; Massarweh, Gassan; Enger, Shirin A.
Characterization of scintillating fibers for use as positron detector in positron emission tomography Journal Article
In: Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB), vol. 65, pp. 114–120, 2019, ISSN: 1724-191X.
Abstract | Links | BibTeX | Tags: Arterial input function, Dynamic PET, Electrons, Positron-Emission Tomography, Radiation detector, Scintillating fibers, Scintillation Counting
@article{turgeon_characterization_2019,
title = {Characterization of scintillating fibers for use as positron detector in positron emission tomography},
author = {Vincent Turgeon and Gustavo Kertzscher and Liam Carroll and Robert Hopewell and Gassan Massarweh and Shirin A. Enger},
doi = {10.1016/j.ejmp.2019.08.009},
issn = {1724-191X},
year = {2019},
date = {2019-09-01},
journal = {Physica medica: PM: an international journal devoted to the applications of physics to medicine and biology: official journal of the Italian Association of Biomedical Physics (AIFB)},
volume = {65},
pages = {114--120},
abstract = {PURPOSE: Manual and automatic blood sampling at different time intervals is considered the gold standard to determine the arterial input function (AIF) in dynamic positron emission tomography (PET). However, blood sampling is characterized by poor time resolution and is an invasive procedure. The aim of this study was to characterize the scintillating fibers used to develop a non-invasive positron detector.
METHODS: The detector consists of a scintillating fiber coupled at each end to transmission fiber-optic cables that are connected to photo multiplier tubes in a dual readout setup. The detector is designed to be wrapped around the wrist of the patient undergoing dynamic PET. The attenuation length and bending losses were measured with excitation from gamma radiation (137Cs) and ultraviolet (UV) light. The response to positron-emitting radio-tracers was evaluated with 18F and 11C.
RESULTS: The attenuation length for a 3.0 m and 1.5 m long scintillating fiber both coincides with the attenuation length given by the manufacturer when excited with the 137Cs source, but not with the UV source due to the differences in scintillation mechanisms. The bending losses are smaller than the measurement uncertainty for the 137Cs source irradiation, and increase when the bending radius decrease for the UV source irradiation. The signal-to-noise ratio for 18F and 11C solutions are 1.98 and 22.54 respectively. The measured decay constant of 11C agrees with its characteristic value.
CONCLUSION: The performed measurements in the dual readout configuration suggest that scintillating fibers may be suitable to determine the AIF non-invasively.},
keywords = {Arterial input function, Dynamic PET, Electrons, Positron-Emission Tomography, Radiation detector, Scintillating fibers, Scintillation Counting},
pubstate = {published},
tppubtype = {article}
}
METHODS: The detector consists of a scintillating fiber coupled at each end to transmission fiber-optic cables that are connected to photo multiplier tubes in a dual readout setup. The detector is designed to be wrapped around the wrist of the patient undergoing dynamic PET. The attenuation length and bending losses were measured with excitation from gamma radiation (137Cs) and ultraviolet (UV) light. The response to positron-emitting radio-tracers was evaluated with 18F and 11C.
RESULTS: The attenuation length for a 3.0 m and 1.5 m long scintillating fiber both coincides with the attenuation length given by the manufacturer when excited with the 137Cs source, but not with the UV source due to the differences in scintillation mechanisms. The bending losses are smaller than the measurement uncertainty for the 137Cs source irradiation, and increase when the bending radius decrease for the UV source irradiation. The signal-to-noise ratio for 18F and 11C solutions are 1.98 and 22.54 respectively. The measured decay constant of 11C agrees with its characteristic value.
CONCLUSION: The performed measurements in the dual readout configuration suggest that scintillating fibers may be suitable to determine the AIF non-invasively.
2017
Famulari, Gabriel; Pater, Piotr; Enger, Shirin A.
Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm Journal Article
In: Physics in Medicine and Biology, vol. 62, no. 13, pp. 5495–5508, 2017, ISSN: 1361-6560.
Abstract | Links | BibTeX | Tags: Algorithms, DNA, DNA Damage, Electrons, Imaging, Monte Carlo Method, Phantoms, Photons, Radiometry
@article{famulari_microdosimetry_2017,
title = {Microdosimetry calculations for monoenergetic electrons using Geant4-DNA combined with a weighted track sampling algorithm},
author = {Gabriel Famulari and Piotr Pater and Shirin A. Enger},
doi = {10.1088/1361-6560/aa71f6},
issn = {1361-6560},
year = {2017},
date = {2017-07-01},
journal = {Physics in Medicine and Biology},
volume = {62},
number = {13},
pages = {5495--5508},
abstract = {The aim of this study was to calculate microdosimetric distributions for low energy electrons simulated using the Monte Carlo track structure code Geant4-DNA. Tracks for monoenergetic electrons with kinetic energies ranging from 100 eV to 1 MeV were simulated in an infinite spherical water phantom using the Geant4-DNA extension included in Geant4 toolkit version 10.2 (patch 02). The microdosimetric distributions were obtained through random sampling of transfer points and overlaying scoring volumes within the associated volume of the tracks. Relative frequency distributions of energy deposition f(textgreaterE)/f(textgreater0) and dose mean lineal energy ([Formula: see text]) values were calculated in nanometer-sized spherical and cylindrical targets. The effects of scoring volume and scoring techniques were examined. The results were compared with published data generated using MOCA8B and KURBUC. Geant4-DNA produces a lower frequency of higher energy deposits than MOCA8B. The [Formula: see text] values calculated with Geant4-DNA are smaller than those calculated using MOCA8B and KURBUC. The differences are mainly due to the lower ionization and excitation cross sections of Geant4-DNA for low energy electrons. To a lesser extent, discrepancies can also be attributed to the implementation in this study of a new and fast scoring technique that differs from that used in previous studies. For the same mean chord length ([Formula: see text]), the [Formula: see text] calculated in cylindrical volumes are larger than those calculated in spherical volumes. The discrepancies due to cross sections and scoring geometries increase with decreasing scoring site dimensions. A new set of [Formula: see text] values has been presented for monoenergetic electrons using a fast track sampling algorithm and the most recent physics models implemented in Geant4-DNA. This dataset can be combined with primary electron spectra to predict the radiation quality of photon and electron beams.},
keywords = {Algorithms, DNA, DNA Damage, Electrons, Imaging, Monte Carlo Method, Phantoms, Photons, Radiometry},
pubstate = {published},
tppubtype = {article}
}
2011
Enger, Shirin A.; D’Amours, Michel; Beaulieu, Luc
Modeling a hypothetical 170Tm source for brachytherapy applications Journal Article
In: Medical Physics, vol. 38, no. 10, pp. 5307–5310, 2011, ISSN: 0094-2405.
Abstract | Links | BibTeX | Tags: Algorithms, Brachytherapy, Computer Simulation, Computer-Assisted, Electrons, Equipment Design, Gold, Humans, Models, Monte Carlo Method, Photons, Platinum, Radioisotopes, Radiotherapy Planning, Stainless Steel, Theoretical, Thulium, Titanium
@article{enger_modeling_2011,
title = {Modeling a hypothetical 170Tm source for brachytherapy applications},
author = {Shirin A. Enger and Michel D'Amours and Luc Beaulieu},
doi = {10.1118/1.3626482},
issn = {0094-2405},
year = {2011},
date = {2011-10-01},
journal = {Medical Physics},
volume = {38},
number = {10},
pages = {5307--5310},
abstract = {PURPOSE: To perform absorbed dose calculations based on Monte Carlo simulations for a hypothetical (170)Tm source and to investigate the influence of encapsulating material on the energy spectrum of the emitted electrons and photons.
METHODS: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of (170)Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical (170)Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation.
RESULTS: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount (textless1%) in water. Platinum encapsulation resulted in bremsstrahlung effects similar to those with the gold encapsulation. The range of the beta particles decreases by 1.1 mm with the stainless-steel encapsulation compared to the bare source but the tissue will still receive dose from the beta particles several millimeters from the source capsule. The gold and platinum capsules not only absorb most of the electrons but also attenuate low energy photons. The mean energy of the photons escaping the core and the stainless-steel capsule is 113 keV while for the gold and platinum the mean energy is 160 keV and 165 keV, respectively.
CONCLUSIONS: A (170)Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our results, the use of (170)Tm as a brachytherapy source presents notable challenges.},
keywords = {Algorithms, Brachytherapy, Computer Simulation, Computer-Assisted, Electrons, Equipment Design, Gold, Humans, Models, Monte Carlo Method, Photons, Platinum, Radioisotopes, Radiotherapy Planning, Stainless Steel, Theoretical, Thulium, Titanium},
pubstate = {published},
tppubtype = {article}
}
METHODS: GEANT4 Monte Carlo code version 9.2 patch 2 was used to simulate the decay process of (170)Tm and to calculate the absorbed dose distribution using the GEANT4 Penelope physics models. A hypothetical (170)Tm source based on the Flexisource brachytherapy design with the active core set as a pure thulium cylinder (length 3.5 mm and diameter 0.6 mm) and different cylindrical source encapsulations (length 5 mm and thickness 0.125 mm) constructed of titanium, stainless-steel, gold, or platinum were simulated. The radial dose function for the line source approximation was calculated following the TG-43U1 formalism for the stainless-steel encapsulation.
RESULTS: For the titanium and stainless-steel encapsulation, 94% of the total bremsstrahlung is produced inside the core, 4.8 and 5.5% in titanium and stainless-steel capsules, respectively, and less than 1% in water. For the gold capsule, 85% is produced inside the core, 14.2% inside the gold capsule, and a negligible amount (textless1%) in water. Platinum encapsulation resulted in bremsstrahlung effects similar to those with the gold encapsulation. The range of the beta particles decreases by 1.1 mm with the stainless-steel encapsulation compared to the bare source but the tissue will still receive dose from the beta particles several millimeters from the source capsule. The gold and platinum capsules not only absorb most of the electrons but also attenuate low energy photons. The mean energy of the photons escaping the core and the stainless-steel capsule is 113 keV while for the gold and platinum the mean energy is 160 keV and 165 keV, respectively.
CONCLUSIONS: A (170)Tm source is primarily a bremsstrahlung source, with the majority of bremsstrahlung photons being generated in the source core and experiencing little attenuation in the source encapsulation. Electrons are efficiently absorbed by the gold and platinum encapsulations. However, for the stainless-steel capsule (or other lower Z encapsulations) electrons will escape. The dose from these electrons is dominant over the photon dose in the first few millimeter but is not taken into account by current standard treatment planning systems. The total energy spectrum of photons emerging from the source depends on the encapsulation composition and results in mean photon energies well above 100 keV. This is higher than the main gamma-ray energy peak at 84 keV. Based on our results, the use of (170)Tm as a brachytherapy source presents notable challenges.